About VMware 2V0-13.25 Exam Braindumps
Nobody welcomes spam, and we do not send it. When you buy VMware Cloud Foundation 9.0 Architect, your email is used for delivery and update notices only, and ExamsTorrent commits to keeping your inbox clean.
VMware 2V0-13.25 Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| Topic 1: Troubleshoot and Optimize the VMware Solution | - Optimization and troubleshooting
|
| Topic 2: Install, Configure, and Administer the VMware Solution | - Implementation and administration
|
| Topic 3: IT Architectures, Technologies, Standards | - Business and technical requirements analysis
|
| Topic 4: Plan and Design the VMware Solution | - Solution planning and design
|
| Topic 5: VMware Products and Solutions | - VMware Cloud Foundation architecture
|
Common VMware Cloud Foundation 9.0 Architect Questions from Candidates
2V0-13.25 is passed with 300, and the official exam fee is $250 USD. Fixing these numbers early helps you set a measurable practice target.
The 2V0-13.25 exam contains 60 questions to complete in 135 minutes minutes. Rehearsing under the same limit on the ExamsTorrent engine turns pacing into a trained habit.
Choose the version of VMware Cloud Foundation 9.0 Architect you want, one, two, or all three, add it to the cart, and complete payment through the secure Credit Card checkout. The download link then arrives by email within about a minute, so your study starts without wasted time.
The package includes 130 practice questions for the 2V0-13.25 exam. The count is set through analysis of a large volume of data, so the set matches the scope of the real test without padding.
- Plan and Design the VMware Solution ()
- Install, Configure, and Administer the VMware Solution ()
- Troubleshoot and Optimize the VMware Solution ()
Divide your time according to each topic's weight.
Payment runs through the Credit Card system, a globally used online payment network. We never share your personal information with third parties without your permission, and we never send spam, so your details stay where they belong.
Recommended knowledge of VMware Cloud Foundation architecture and hands-on experience with VMware solutions. Official training course recommended.
VMware Cloud Foundation 9.0 Architect Sample Questions:
An architect is responsible for designing a VMware Cloud Foundation (VCF) Private Cloud.
During a requirements gathering workshop with key customer stakeholders, the following information was captured:
- The service catalog solution must meet a minimum availability SLA of
99.9%.
- The performance of the service catalog solution must not be impacted
by maintenance activities or a single physical ESXi host failure.
During the logical design phase of the project, the following design decisions were made:
- The solution will deploy VCF Automation using the highly available
deployment model.
Which two corresponding physical design decisions should the architect make to meet the stated requirements? (Choose two.)
- A. The solution will configure the external load balancer to send all traffic to the native Kubernetes load balancer.
- B. The solution will deploy three VCF Automation appliances using the small size.
- C. The solution will create a VM-host anti-affinity rule to ensure all nodes of the VCF Automation cluster are located on different ESXi hosts.
- D. The solution will deploy an external load balancer to replace the native load balancer.
- E. The solution will create a VM-host affinity rule to ensure all nodes of the VCF Automation cluster are located on the same ESXi host.
Correct Answer: C,D 🗳️
Explanation: Only visible for ExamsTorrent members. You can sign-up / login (it's free).
Which VMware Cloud Foundation (VCF) Storage Model can be deployed to scale storage capacity independent of compute and network?
- A. vSAN ESA Storage Cluster Model
- B. vSAN Capacity Cluster Model
- C. vSAN ESA Storage Model
- D. vSAN Compute Cluster Storage Model
Correct Answer: A 🗳️
An organization is designing a VMware Cloud Foundation (VCF) solution hosting a business- critical database. The application owners specified the following requirements:
- All workload domains will use vSAN for storage.
- A maximum acceptable data loss of 5 minutes (Recovery Point Objective (RPO) = 5 minutes)
- An automated failover in case of a site outage where Recovery Time
Objective should not exceed 30 minutes.
- The performance impact should be minimized.
Which design approach aligns with the application's requirement?
- A. Use vSAN stretched cluster.
- B. Use asynchronous replication with snapshots taken every 30 minutes to reduce storage impact.
- C. Use synchronous replication on the storage array level.
- D. Configure backup-based recovery with backup jobs scheduler set to every 30 minutes.
Correct Answer: A 🗳️
Explanation: Only visible for ExamsTorrent members. You can sign-up / login (it's free).
An architect has been tasked with designing a new VMware Cloud Foundation (VCF) solution.
During the requirements gathering workshops with the customer, the following requirements were captured:
REQ01: The solution must support workloads being deployed to multiple
physical datacenter locations (DC01, DC02).
REQ02: The solution must support the use of the two factor
authentication for authenticating user access to the administrative
tools.
REQ03: The solution must prioritize reducing the operational overhead
associated with managing the deployed infrastructure platform.
A combination of which two design decisions should the architect document for the VCF Single Sign-On architecture in order to meet these requirements? (Choose two.)
- A. Configure all additional VCF instances in the same region to point to the VIDB in the first VCF instance at DC02.
- B. Deploy VCF Identity Broker (VIDB) in the first VCF instance management domain at DC01.
- C. Deploy VCF Identity Broker (VIDB) in the management domain of every VCF instance in all sites.
- D. Deploy VCF Identity Broker (VIDB) in the management domain of each VCF instance at DC02.
- E. Configure all additional VCF instances in the same private cloud to point to the VIDB in the first VCF instance at DC01.
Correct Answer: B,E 🗳️
Explanation: Only visible for ExamsTorrent members. You can sign-up / login (it's free).
An architect is responsible for designing a VMware Cloud Foundation (VCF)-based solution for a customer. The customer has the following requirement:
There should be no single points of failure within the solution.
To comply with the customer requirement, the architect has decided to include physical NIC teaming for all ESX servers in the design.
When documenting this design decision, which consideration should the architect make?
- A. Embedded NICs should not be used for NIC teaming.
- B. Each NIC team must include NICs from the same physical NIC Card.
- C. Only 10GbE NICs should be used for NIC teaming.
- D. Each NIC team must include NICs from different physical NIC Cards.
Correct Answer: D 🗳️
Explanation: Only visible for ExamsTorrent members. You can sign-up / login (it's free).
Free Demo





